| Fully
weatherproof metal detector |
| METOR
120 WP Applications |
| Outdoor
security applications, e.g. stadiums, concerts, prisons,
police (VIP protection), amusement parks |
| METOR
120 WP technical specifications |
|
Conformity:
|
METOR
conforms with the low voltage directive and the EMC
directive.
It
meets the requirements of the following standards: |
| Safety
standards: |
| |
EN
60950 Electrical safety. |
| EMC
standards: |
| |
EN
50081-1 (Emission), EN 50082-1 (Immunity) |
| Other
standards: |
| |
NILECJ-0601,
security levels 1-5 (covers the design and performance
of walk-through metal detectors)
Safe
for wearers of heart pacemakers, pregnant women and
magnetic recording materials.
|
|
Specifications:
|
| Ambient
operating temperature: |
| |
-10°C
to +55°C (14°F to 131°F). -30°C to +55°C
(-22°F to 131°F) with optional heater. |
| Humidity: |
| |
Up
to 100%. |
| Protection: |
| |
IP
65 (IEC 529). |
| Power
supply: |
| |
Mains:95
- 250 VAC, 50 or 60 Hz. Battery 20 - 30 VDC. Consumption
35W, 235W with optional heater. Fuse TIA 5x20
mm. Optional display unit. |
| Alarm
indications: |
| |
Red
light alarm. Light column display for relative
object size. Adjustable volume and tone for audible
alarm. |
| Fault
indication: |
| |
Self
diagnostics displays the fault code on the display
unit. |
| Controls: |
| |
See
control unit. Mains on/off switch. 50/60 Hz frequency
selection. |
| Remote
alarm: |
| |
Remote
alarm relay (SPDT). Voltage free contact with
T2A fuse 5x20 mm. Optional display unit. |
| Warranty: |
| |
Two
years |
|
Weights:
|
| Total
shipping weight: |
| |
64.2
kg (141.6 lbs) |
| Total
shipping volume: |
| |
0.33
m3 (11.8 cu ft) |
| Net
weight: |
| |
51.7
kg (114 lbs) |
| Coils: |
| shipping
weight: |
| |
41.5
kg (91.5 lbs) |
| shipping
volume |
| |
0.21
m3 (7.5 cu ft) |
| Cross
piece + electronics: |
| shipping
weight |
| |
22.7
kg (50.1 lbs) |
| shipping
volume |
| |
0.12
m3 (4.3 cu ft) |